{"id":416,"date":"2026-09-09T11:13:23","date_gmt":"2026-09-09T11:13:23","guid":{"rendered":"https:\/\/carrera.uptoo.top\/konvektor-chy-radiator\/"},"modified":"2026-10-25T07:13:34","modified_gmt":"2026-10-25T07:13:34","slug":"konvektor-chy-radiator","status":"publish","type":"page","link":"https:\/\/carrera.uptoo.top\/en\/haidy\/konvektor-chy-radiator\/","title":{"rendered":"A convector or a radiator under the window"},"content":{"rendered":"<div class=\"wrap phead\">\n  <div class=\"crumb\"><a href=\"\/en\/\">Home<\/a><span>\/<\/span><a href=\"\/en\/haidy\/\">Guides<\/a><span>\/<\/span><b>Convector or radiator<\/b><\/div>\n  <h1 data-motion-text=\"words\">A convector or a radiator under the window<\/h1>    <div class=\"answer\" data-reveal=\"fade-up\"><b>In brief:<\/b> Short answer: if the glazing goes to the floor, there is nowhere to hang a radiator, and an in-floor convector in the screed works; and when the screed is already poured, a floor-standing FRH or a skirting BR. With an ordinary window with a sill, a radiator is simpler to install and no worse: the choice is dictated by geometry and the coolant mode, not by \u201cwhich is better in general\u201d.<\/div><\/div>\n<section class=\"sec-tight\"><div class=\"wrap\"><div class=\"prose\" data-reveal=\"fade-up\">\n  <p>Both devices give the room the heat of the water from the circuit, and by an ordinary window a resident won&#8217;t feel the difference. It appears in three places: whether there is somewhere to put the unit, what happens to the output at a low supply, and whether the floor can still be touched.<\/p>\n  <h2>Where they really differ<\/h2>\n  <div class=\"tscroll\"><table class=\"dtable\">\n    <tr><th>Criterion<\/th><th>In-floor convector<\/th><th>Radiator<\/th><\/tr>\n    <tr><td>Floor-to-ceiling glazing<\/td><td>The casing lies in the screed under the glass, grille on top<\/td><td>There is no wall under the glass, nowhere to hang it<\/td><\/tr>\n    <tr><td>Appearance<\/td><td>Only the grille is visible<\/td><td>The device is on the wall<\/td><\/tr>\n    <tr><td>Installation<\/td><td>Set into the screed at the design stage<\/td><td>Hung at any time<\/td><\/tr>\n    <tr><td>Cold from the glass<\/td><td>A curtain along the glass, if the length is close to its width<\/td><td>Heats where it hangs<\/td><\/tr>\n    <tr><td>Finished floor<\/td><td>Too late: the screed can&#8217;t be redone<\/td><td>Can be installed<\/td><\/tr>\n    <tr><td>Low supply, 45\/35<\/td><td>Output without a fan drops threefold<\/td><td>Also drops: the physics is the same<\/td><\/tr>\n  <\/table><\/div>\n  <h2>When a radiator is the right choice<\/h2>\n  <p>An ordinary window with a sill, the renovation is done, nobody is going to raise the floor, the pipes are easily run to the wall. In this case a radiator does the same job more simply, and we won&#8217;t talk you into an in-floor convector. There&#8217;s also an argument in its favour: a radiator gives off part of its heat as radiation, and this is felt when a person sits nearby for a long time.<\/p>\n  <h2>Floor-to-ceiling glass, but the screed is already poured<\/h2>\n  <p>A radiator is not the only option here. Carrera has a <a href=\"\/en\/pidlohovi\/\">floor-standing FRH<\/a> that is placed right in front of the glass, and a <a href=\"\/en\/plintusni\/\">skirting BR<\/a> along the wall. The principle is the same, a curtain along the glass, but the floor doesn&#8217;t need to be opened up.<\/p>\n  <div class=\"tscroll\"><table class=\"dtable\">\n    <tr><th>Device<\/th><th>Width \u00d7 height, mm<\/th><th>W per 1000 mm, 45\/35<\/th><\/tr>\n    <tr><td>M\/C 65, in the screed<\/td><td>230 \u00d7 65<\/td><td class=\"num\">82<\/td><\/tr>\n    <tr><td>S\/C 90, in the screed<\/td><td>230 \u00d7 90<\/td><td class=\"num\">101<\/td><\/tr>\n    <tr><td>FRH, on the floor<\/td><td>148 \u00d7 175<\/td><td class=\"num\">123<\/td><\/tr>\n    <tr><td>FR2H, on the floor<\/td><td>290 \u00d7 175<\/td><td class=\"num\">169<\/td><\/tr>\n    <tr><td>BR 18, skirting<\/td><td>60 \u00d7 180<\/td><td class=\"num\">77<\/td><\/tr>\n    <tr><td>BR 21, skirting<\/td><td>60 \u00d7 210<\/td><td class=\"num\">97<\/td><\/tr>\n  <\/table><\/div>\n  <p>All of this is natural convection. One mode is taken, 45\/35, because in our tables in-floor units are given for 85\/75 and 65\/55, while floor-standing and skirting ones for 90\/70 and 70\/50: the \u201cper metre\u201d catalogue figures can&#8217;t be placed side by side. At 45\/35 the spread is 77\u2013169 W, so the type is chosen by location and appearance, and the output is matched by length.<\/p>\n  <h2>Where people go wrong and when a convector is not suitable<\/h2>\n  <ul>\n    <li><b>A catalogue figure instead of the mode.<\/b> S\/C 90, 2000 mm long, without a fan gives 770 W at 85\/75, 513 W at 65\/55 and 256 W at 45\/35. A heat pump usually runs at 45\/35, so the 45\/35 row is taken for it: a version with a fan (SV 90 at 30% speed gives 569 W here) or a longer unit. A radiator isn&#8217;t saved from this arithmetic either; in more detail in the review of <a href=\"\/en\/teplovyi-nasos-konvektor-45-35\/\">a convector on a heat pump<\/a>.<\/li>\n    <li><b>A decision after the screed is poured.<\/b> A casing can&#8217;t be laid in a finished floor: what remains is FRH, BR or a radiator.<\/li>\n    <li><b>A thin screed.<\/b> The lowest casing is 65 mm. If the depth is less, there is no in-floor series for you.<\/li>\n    <li><b>Heating is turned on infrequently.<\/b> For an office or a shop, what matters is the speed of reaching the mode, not the sill; this is a separate <a href=\"\/en\/konvektor-chy-radiator-neravnomirnyi-rezhym\/\">review for an irregular schedule<\/a>.<\/li>\n  <\/ul>\n  <h2>What to check before deciding<\/h2>\n  <ul>\n    <li>What is under the glass: a pier or the floor. Measure the height from the floor to the bottom of the glass.<\/li>\n    <li>The screed: poured or not, and what depth exactly under the glass, not in the middle of the room.<\/li>\n    <li>Supply and return in writing for the coldest day: 85\/75, 65\/55 or 45\/35.<\/li>\n    <li>The output is taken from the row for your mode, not from the top catalogue figure.<\/li>\n    <li>For a version with a fan: a 24 V line and space for the power supply and thermostat.<\/li>\n    <li>The order of magnitude is given by the <a href=\"\/en\/kalkulyator\/\">output calculator<\/a>; the final selection is confirmed by an engineer.<\/li>\n  <\/ul>\n<\/div>\n<div class=\"faq\" data-reveal=\"fade-up\" style=\"margin-top:26px\">\n  <details open><summary>Can a radiator be placed under a panoramic window?<\/summary><p>Yes, if there is a pier under the glass: the radiator is hung on it. When the glass goes to the floor, there is no pier, and what remains is a convector in the screed or FRH or BR in front of the glass.<\/p><\/details>\n  <details><summary>Is an in-floor convector needed if the heating is on a heat pump?<\/summary><p>What&#8217;s needed is not a specific device but the table row for 45\/35. S\/C 90 at 2000 mm without a fan gives 256 W there versus 770 W at 85\/75, so for a heat pump a version with a fan or extra length is taken.<\/p><\/details>\n  <details><summary>Can a convector be added to a finished renovation?<\/summary><p>An in-floor one, no: it needs a screed. FRH and BR are placed on a finished covering, which won&#8217;t have to be opened up.<\/p><\/details>\n  <details><summary>Does a convector make noise compared with a radiator?<\/summary><p>Natural convection is silent. A fan makes noise: SV 90 at 30% speed gives 19.8\u201324.3 dB, at 100% up to 46.0 dB (range by lengths 1000\u20133000 mm).<\/p><\/details>\n<\/div>\n<div style=\"margin-top:30px\"><a class=\"btn btn-primary\" data-magnetic data-go=\"category\" href=\"\/en\/vnutrishnopidlohovi\/\">View in-floor models<svg class=\"ico\" viewBox=\"0 0 24 24\"><path d=\"M5 12h14M13 6l6 6-6 6\"\/><\/svg><\/a><\/div>\n<\/div><\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":0,"featured_media":0,"parent":388,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-416","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A convector or a radiator under the window - Carrera (staging)<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A convector or a radiator under the window - Carrera (staging)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/carrera.uptoo.top\/en\/haidy\/konvektor-chy-radiator\/\" \/>\n<meta property=\"og:site_name\" content=\"Carrera (staging)\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-25T07:13:34+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"A convector or a radiator under the window - Carrera (staging)","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"A convector or a radiator under the window - Carrera (staging)","og_url":"https:\/\/carrera.uptoo.top\/en\/haidy\/konvektor-chy-radiator\/","og_site_name":"Carrera (staging)","article_modified_time":"2026-10-25T07:13:34+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[]}},"_links":{"self":[{"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/pages\/416","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/types\/page"}],"replies":[{"embeddable":true,"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/comments?post=416"}],"version-history":[{"count":1,"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/pages\/416\/revisions"}],"predecessor-version":[{"id":420,"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/pages\/416\/revisions\/420"}],"up":[{"embeddable":true,"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/pages\/388"}],"wp:attachment":[{"href":"https:\/\/carrera.uptoo.top\/en\/wp-json\/wp\/v2\/media?parent=416"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}