Carrera FRH floor-standing water convector
Stands on the floor by a window with a low sill — installation without a screed or building work. FR2H with two heat exchangers gives up to 3204 W.
Painting in any RAL colour

When to choose FRH
The renovation is done, nobody is redoing the screed, and the panoramic glazing is left without a thermal curtain. FRH is placed on a finished floor and works just like an in-floor one — only above the floor.
Series features
Installation without a screed
The unit stands on legs by the glazing — placed in a finished room without building work.

Three line versions
FRH with one heat exchanger, FR2H with two (up to 3204 W), 4FRH — four-tube.

Casing to match the interior
The standard is white with a “Satin” grille; any RAL and a shagreen texture — to order.

What's included

Floor-standing convectors Carrera FRH — a heat source in the room
Floor-standing convectors by CARRERA are the ideal solution for heating rooms with stained-glass glazing or rooms with low sills, to create a barrier against cold air entering the room, and also to emphasise the design and optimise the space — all of this is made possible by the line of modern Carrera FRH convectors. Floor-standing convectors are used as the main heat source and make it easy to solve tasks thanks to the large number of models with various designs, with the possibility of painting the casing according to the RAL palette.
Specifications of the floor-standing convector casing with a two-tube heat exchanger
Floor-standing convectors Carrera FRH are a casing made of high-quality steel 1 mm thick, painted with a wear-resistant powder coating. Two-tube heat exchangers using a copper tube 22 mm in diameter with a 1 mm wall thickness are installed in the FRH casing. All heat exchangers are manufactured and undergo outgoing inspection at the factory. It consists of high-quality components (copper and aluminium) from European manufacturers. The compact and well-thought-out heat-exchanger design makes it possible to provide heat to a larger room area. It also serves the function of stiffening ribs thanks to the cassette design of the heat-exchanger mountings and supports, and is easy to service thanks to the removable convector cover. It is possible to increase the heat output by using 2 or 3 heat exchangers, with horizontal and vertical arrangement.
Connection features and convenient control
A distinctive feature is the concealed connection of the heating pipes in the convector legs and the placement of the regulating fittings. To regulate the room temperature, heat-regulating valves and thermostatic heads from European manufacturers are used (available for versions with the + T index). The convector cover is closed with decorative grilles made of anodised aluminium (Satin colour).
Specifications
| Installation | On the floor, by the glazing |
| Versions | FRH (1 HE) · FR2H (2 HE) · 4FRH (4 tubes) |
| Casing | Steel, white; painting in any RAL; shagreen — optional |
| Grille | Metal “Satin” |
| Coolant | 40–90 °C · up to 10 bar |
| Lengths | 1000–2250 mm |
Output by length
| Coolant | 1000 mm | 1500 mm | 2000 mm | 2250 mm |
|---|---|---|---|---|
| FRH · 90/70 °C | 722 W | 1261 W | 1811 W | 2086 W |
| FRH · 70/50 °C | 376 W | 656 W | 943 W | 1086 W |
| FR2H · 90/70 °C | 1109 W | 1933 W | 2784 W | 3204 W |
| FR2H · 70/50 °C | 554 W | 966 W | 1392 W | 1602 W |
Casing colour options
The casing and grille are painted in any colour from the RAL palette. Below are the popular options.
Grilles
The grille is supplied matching the casing per the RAL palette or in contrast; the length — to the unit size. The full selection and materials — in the Grilles section.